The following is an overview of Eclat’s environmental performance indicators relating to our production sites, including R&D centers, offices, and headquarters occupied by 16,000+ employees across Asia.
The management systems are audited by third-party certification agencies every year.
Headquarters
Gigajoule (gJ) corporate emissions
2023
2024
2025
Gasoline (92 or 95)
8,231
7,299
6,875
Diesel
111
74
104
Natural Gas
782
780
845
Electricity
11,881
11,879
11,712
Renewable energy
55
93
98
Total
21,060
20,125
19,634
Material Division
GigaJoule (gJ) energy consumption
2023
2024
2025
Non-renewable energy
1,033,341.597
1,094,771.297
1,034,133.659
Renewable energy
11,068.803
19,128.715
30,473.482
Total energy consumption
1,044,410.400
1,113,900.012
1,064,607.141
Total throughput (ton)
23,980
25,783
26,596
Energy intensity (GJ/ton)
43.553
43.203
40.029
Garment Division
Gigajoule (gJ) energy consumption
2023
2024
2025
Non-renewable energy
96,718.430
115,366.472
124,977.909
Renewable energy
4,557.146
4,779.623
5,491.314
Total energy consumption
101,275.576
120,146.095
130,469.223
Total throughput (dozen)
4,435,183
5,964,852
6,603,167
Energy intensity (GJ/dozen)
0.0228
0.0201
0.0198
Corporate Greenhouse Gas (GHG)
Emissions (t-CO₂e)
2023
2024
2025
Corporation
Scope 1 + 2 (Direct and Energy Indirect GHG Emissions)
1187,785.91
12,998.68
110,522.25
Scope 3 Other Indirect GHG Emissions
9,881.73
10,535.73
26,195.25
Material Division
Scope 1 + 2 (Direct and Energy Indirect GHG Emissions)
99,969.05
100,415.67
83,860.05
Total throughout (ton)
23,980
25,783
26,596
Emission intensity (t-CO₂e/ton)
4.17
3.89
3.15
Garment Division
Scope 1 + 2 (Direct and Energy Indirect GHG Emissions)
19,377.48
23,011.03
24,022.92
Total throughout (dozen)
4,435,183
5,964,852
6,603.167
Emission intensity (t-CO₂e/thousand dozen)
4.37
3.85
3.64
Scope 1 refers to direct emissions of greenhouse gas.
Scope 2 refers to indirect energy emissions of greenhouse gas.
Scope 3 refers to other indirect greenhouse gas emissions (including employees’ overseas travel, waste removal, and disposal, upstream raw materials, raw materials, product transportation, etc.).
Eclat follows ISO 14064-1:2006 and the Greenhouse Gas Emission Coefficient Management Table 6.0.4 from the Environmental Protection Administration to calculate its greenhouse gas emissions, including the six main gases (carbon dioxide, methane, nitrous oxide, hydrofluorocarbon, perfluorinated carbon, and sulphur hexafluoride) and nitrogen trifluoride. These calculations are used to determine the company’s emission coefficient and Global Warming Potential.
Eclat adopts the operational control approach while summarizing greenhouse gas emissions and therefore, 100% of the emissions in the inventory are recognized.
Sources of the Scope 1 direct greenhouse gas emissions include natural gas, bituminous coal, diesel, and gasoline.
The electricity emission coefficients for facilities in Taiwan are determined by the Bureau of Energy under the Ministry of Economic Affairs, while those for facilities in Vietnam are determined by the Meteorology, Water, and Climate Change Bureau under the Energy and Environment Department of Vietnam. The emission coefficient for externally purchased steam is provided by Ta-Yuan Cogen Co., Ltd.
Energy conservation and carbon reduction proposal
Energy conservation approach
Carbon reduced (t-CO₂e per year)
Dayuan Factory
Added 14 new low-bath-ratio machines to replace conventional dyeing machines, reducing electricity and steam consumption.
1,945.86
Constructed solar power installations 749.25 kWp
428.85
Hsi-Chou Factory
Installation of a Variable Frequency Drive (VFD) on LTG Spray Motor
85.6
Constructed solar power installations 1746.76 kWp
1,151.57
Eclat Fabrics Vietnam
Constructed Phase II solar power installations 4200 kWp
1,430.53
E-TOP Factory
Replaced LED light
24.36
Constructed solar power installations 1236 kWp
898.30
PT. Eclat Textile
Replaced diesel boilers with electric heating irons
160.89
Total
4,974.15
Solar power is based on an annual generation of 33,924 KWH and is calculated with the solar power carbon reduction coefficient announced by the Vietnamese Government (605/KTTVBDKH-GSPT).
Taiwan’s electricity emission factor: 0.495 kg CO2e/kWh; Vietnam: 0.7221 kg CO2e/kWh; Indonesia: 0.877 kg CO2e/kWh.
The calculation method involves taking the reduction in electricity usage compared to the previous year, and converting it to a carbon reduction amount using a coefficient
Material Division
Kilograms (kg) waste generated and recycled
General business waste
2023
2024
2025
Recycling and Treatment
10,024,478
10,049,618
9,294,364
Incineration
20,790
45,110
132,870
Landfill Disposal
270,080
228,950
224,600
Total
10,315,348
10,323,678
9,651,834
Hazardous Business Waste (For Eclat Fabric Vietnam only)
2023
2024
2025
Recycling and Treatment
162,190
93,550
98,040
Incineration
58,200
170,470
186,840
Landfill Disposal
3,758
0
0
Total
224,148
264,020
284,880
In light of the local regulatory requirements in Vietnam, hazardous business waste is only applicable to Eclat Fabric Vietnam.